A clever convenience feature is the . This optional accessory can read all the parameters from one controller and write them to another. For a technician setting up multiple identical units, this function alone justifies the search for a detailed guide. It saves immense time and prevents manual configuration errors.
This is the heart of the repack. The original manual lists 60+ parameters; the repack organizes them into logical groups:
| Terminal | Description | | --- | --- | | 1-2 | Power supply (24V AC/DC) | | 3-4 | Sensor input 1 ( thermocouple or PT100) | | 5-6 | Sensor input 2 (optional) | | 7-8 | Relay output 1 (heating/cooling) | | 9-10 | Analog output (optional) | eliwell sb655 c manual repack
: Equipped with 5 analogue probe inputs (supporting NTC/PTC sensors), 6 digital inputs for safety line monitoring, and 6 digital relay outputs to actuate compressors and water pumps.
The Eliwell SB655/C Go to product viewer dialog for this item. A clever convenience feature is the
Disengage the internal plastic clips securing the rear terminal backing to the main body.
: Integrated RS-485 serial communication port supporting Modbus and Televis. Hardware Architecture Overview Specification Details Power Supply 12–24V~ (AC) / 24V= (DC) Circuit Capacity Up to 2 independent refrigerant circuits Compressor Limits Up to 4 capacity steps (Scroll, Semi-Hermetic, Screw) Analog Inputs 5 configurable inputs (NTC, 4–20mA, or 0–10V) Digital Outputs Up to 6 configurable relays (model dependent) Network Support Modbus-RTU, Televis, and Miconet 🔌 Wiring & Terminal Map Configuration It saves immense time and prevents manual configuration
+-------------------------------------------------------------+ | [1][2][3] [4][5] [6][7][8][9][10] [A][B] | | Power Supply Auxiliary Analog Inputs TTL/RS-485 Port | | 12-24V~ 5V/12V DC (Probes/Sensors) Copy Card Conn. | +-------------------------------------------------------------+ | [11][12] [13][14] [15][16] [17][18] [19][20] | | Relay 1 Relay 2 Relay 3 Relay 4 Relay 5/6 | | (Comp 1) (Comp 2) (Fan Low) (Fan High) (Alarm/Pump) | +-------------------------------------------------------------+ Critical Connections: : 12-24V~ or 24V= source.
Manually repacking an Eliwell SB655 C is a straightforward process of data entry, but it requires attention to detail. Always verify the probe type and defrost settings first, as these are the most common causes of system failure after a reset.
: Includes a serial connection for integration with plant supervision systems and supports Modbus and Televis protocols.